blast auxiliary customer serviceA few basic principles for Air conditioner troubleshooting. For both main home blast auxiliary portable ac unit or maybe window air conditioners, the first thing to check is whether the system is growing adequate strength. If the unit utilizes 220 volt power be sure that the correct voltage is getting to the unit. Exact same for 110 volt units. A voltage meter is generally used to assure the voltage is correct.
For window air cooling units the voltage can also be checked before as well as after the thermostat. If voltage is being provided with the thermostat yet not from it then the thermostat most likely needs replaced. This is a rather common problem. Another place to check is the fan motor voltage. The fan on window air conditioners runs both the indoor blower and the condenser fan. If that motor fails than the compressor could run for a short time, but will overheat and turn off. Continued operation like this is going to result in compressor failure. This particular electric motor could be economically replaced for bigger window air conditioners, but for smaller ones the cost of substitute will be more than a brand new device.
Central Air Conditioners for the house tend to be more complex and there are more things which may go wrong. Like with the window air conditioner the thermostat can additionally be a problem. The main air conditioner thermostat will only have 24 volts shopping at it. And so do not search for high voltage there. A number of units the voltage is going to be coming from the backyard system as well as others the voltage would be furnished by the indoor air handler or even furnace. Most home central air conditioning would be offered by the indoor air handler or maybe the furnace. If the air conditioner is for cooling only the unit will most likely have only two wires going to the condenser system. Make sure that you have 24 volts across those cables.
The next step to check will be the inside blower. If perhaps your thermostat is demanding cooling then the indoor blower must be turned on. If there’s no air going across the indoor cooling coil then you will quickly have a big block of ice created on the coil. This might happen for a few reasons. The interior blower is not working, the air flow is restricted and not allowing air to go across the coil. A clogged air filter would in addition accomplish this. Or the outdoor condenser device has lost the cost of refrigerant.
Lastly and worst of all occurs when you’ve a comprehensive compressor failure. Often if this takes place the compressor will “lock up” or not be able to flip when power is supplied to it. Overheating or lack of lubrication are typically the main factors behind compressor failure. Overheating can be brought on by the backyard coil around the compressor getting plugged with dirt, leaves, grass, or just basic grime. The outdoor coil needs to be washed out yearly with a very good coil cleaner and water. This helps stop compressor failure as well as help preserve the product operating at peak efficiency. Changing an air cooler compressor is a task that needs specialized equipment and needs to be done by an expert with the proper refrigeration license.
As you can see there a few simple things which a good handyman or homeowner is able to check. There’s also some things which require the specific experience and tools of the professional.